Surtron 120

SURTRON 120 is a high frequency electrosurgical equipment which is suitable to light and medium surgery.

SURTRON 120, through its performance, allows pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and, with a special adapter, BIPOLAR coagulation.

The digital reading of delivered power and the monitoring of operative function by microcontroller guarantees the absolute reliability of working conditions.

 

SURTRON 120 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used.

The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the monopolar output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field.

FEATURES
Code 10100.201
Max output power CUT
120 W-250 Ω
Max output power BLEND
90 W-200 Ω

Max output power FORCED COAG
80W-150Ω
Max output power SOFT COAG
60 W-100 Ω
Max output power BIPOLAR
40 W-100 Ω
Working frequency 600 KHz
Patient circuit F
Selectable input voltage 115-230 Vac
Mains frequency 50-60 Hz
Electrical input power 300 VA
Size WxHxD  254x104x288 mm
Weight 5 Kgs

Categories: , Tag:

SURTRON 120 is a high frequency electrosurgical equipment which is suitable to light and medium surgery.

SURTRON 120, through its performance, allows pure CUT, cut-coagulation BLEND, superficial coagulation FORCED COAG, deep coagulation in absence of necrosis SOFT COAG and, with a special adapter, BIPOLAR coagulation.

The digital reading of delivered power and the monitoring of operative function by microcontroller guarantees the absolute reliability of working conditions.

SURTRON 120 allows a highly professional surgery thanks to the user-friendly and safety solutions normally used.

The connection of neutral electrode is constantly monitored. Safety control of patient/plate contact using split neutral electrode. The possibility to control by the handle the monopolar output functions as well as the delivery of output power, allows to implement the surgical operation without turning away the surgeon attention from the surgical field.

FEATURES
Code 10100.201
Max output power CUT
120 W-250 Ω
Max output power BLEND
90 W-200 Ω

Max output power FORCED COAG
80W-150Ω
Max output power SOFT COAG
60 W-100 Ω
Max output power BIPOLAR
40 W-100 Ω
Working frequency 600 KHz
Patient circuit F
Selectable input voltage 115-230 Vac
Mains frequency 50-60 Hz
Electrical input power 300 VA
Size WxHxD  254x104x288 mm
Weight 5 Kgs